Points to note when using acid copper brightener flake

2025-08-26 22:48:27

Recently, many plating factories have sent us their potions for proofing and analyzing. When using acid copper brightener for Hull tank test, we found that there are two matters that will have an impact on the proofing results, so we decided to write an article to share this knowledge with our readers and hope that it will help them.

Selection of power supply

①Hull tank power supply equipment, must have both current and voltage display. When the current is the same, the lower the voltage, the higher the conductivity of the plating solution. For the plating solution with acid copper brightener, 2A stirring plating, the normal test voltage should be 3.0~3.2V (related to the diameter of the external circuit used).

If the test voltage is higher than 3.5V, there must be less sulfuric acid; if it is lower than 3.0V, there must be more sulfuric acid. Through the voltage data, we can roughly determine the amount of sulfuric acid.

②It is recommended to have a time preset timer with an audible alarm, which frees up more energy to do other things. On the other hand, there will always be times when you are not sure of the time, which will affect the reproducibility of the test.

About us

Guangdong Bigely Technology Co., Ltd. ,founded in 2003, is a high-tech enterprise integrating R & D,production, sales and service, specializing in the production of electroplating additives. As a famous electroplating additives source manufacturer in China, our products have passed ISO9001, ISO14001, OHSAS18001 management system certification and the test of Swiss SGS company and we also possess 2 national invention patents and 6 utility model patents.

If you need our high-quality electroplating additives, please contact us. We can provide you samples for test, and also provide a series of services.